Detected entrypoint: 'index.circuit.tsx'
trace: `key` is not a prop. Trying to access it will result in `undefined` being returned. If you need to access the same value within the child component, you should pass it as a different prop. (https://react.dev/link/special-props)
<SchematicBoxPositions>
<SchematicBoxPlacement componentName="C1" positionAnchor="center" schX="-4" schY="-18" width="0.9" height="0.6" />
<SchematicBoxPlacement componentName="C2" positionAnchor="center" schX="0" schY="-18" width="0.9" height="0.6" />
<SchematicBoxPlacement componentName="R1" positionAnchor="center" schX="4" schY="-18" width="0.6" height="0.65" />
<SchematicBoxPlacement componentName="LED1" positionAnchor="center" schX="8" schY="-18" width="1.13" height="0.65" />
<SchematicBoxPlacement componentName="JI1" positionAnchor="center" schX="-26" schY="13" width="1.4" height="0.8" />
<SchematicBoxPlacement componentName="RI1" positionAnchor="center" schX="-21" schY="13" width="0.6" height="0.65" />
<SchematicBoxPlacement componentName="CF1" positionAnchor="center" schX="-16" schY="13" width="0.9" height="0.6" />
<SchematicBoxPlacement componentName="JI2" positionAnchor="center" schX="-26" schY="-4" width="1.4" height="0.8" />
<SchematicBoxPlacement componentName="RI2" positionAnchor="center" schX="-21" schY="-4" width="0.6" height="0.65" />
<SchematicBoxPlacement componentName="CF2" positionAnchor="center" schX="-16" schY="-4" width="0.9" height="0.6" />
<SchematicBoxPlacement componentName="JI3" positionAnchor="center" schX="14" schY="-4" width="1.4" height="0.8" />
<SchematicBoxPlacement componentName="RI3" positionAnchor="center" schX="19" schY="-4" width="0.6" height="0.65" />
<SchematicBoxPlacement componentName="CF3" positionAnchor="center" schX="24" schY="-4" width="0.9" height="0.6" />
<SchematicBoxPlacement componentName="JI4" positionAnchor="center" schX="14" schY="13" width="1.4" height="0.8" />
<SchematicBoxPlacement componentName="RI4" positionAnchor="center" schX="19" schY="13" width="0.6" height="0.65" />
<SchematicBoxPlacement componentName="CF4" positionAnchor="center" schX="24" schY="13" width="0.9" height="0.6" />
</SchematicBoxPositions>
<SchematicPlacementIssues>
<TwoPinComponentHasInvertedRails componentName="C1" railPin="pin1" railType="power" deltaSchRotation="180" suggestedRailFacingDirection="up" message="rotate C1 by 180° so its positive-supply pin faces up and its ground pin faces down; preserve pin connections and reroute attached traces" />
<TwoPinComponentHasInvertedRails componentName="C2" railPin="pin1" railType="power" deltaSchRotation="180" suggestedRailFacingDirection="up" message="rotate C2 by 180° so its positive-supply pin faces up and its ground pin faces down; preserve pin connections and reroute attached traces" />
<TwoPinComponentShouldBeVertical componentName="R1" railPin="pin1" railType="power" deltaSchRotation="-90" suggestedRailFacingDirection="up" message="rotate R1 by -90° so its power-connected pin faces up and the component is vertical" />
<TwoPinComponentShouldBeVertical componentName="LED1" railPin="pin2" railType="ground" deltaSchRotation="-90" suggestedRailFacingDirection="down" message="rotate LED1 by -90° so its ground-connected pin faces down and the component is vertical" />
<DecouplingCapacitorsNotCloseTogether rail="V5" ground="GND" capacitorNames="C1, C2" maxBodyGap="3.1" maxRecommendedBodyGap="1" message="Group the decoupling capacitors between V5 and GND closer together in this schematic block. Preserve their net connections." />
<RailPathTooSpreadOut hostName="JI1" pinName="IN" railType="ground" pathSpan="8.9" pathLength="18.52" message="Visible path from JI1.IN to ground spans 8.90 schematic units; move the connected support elements closer together near the pin and recompute their schematic traces." />
<RailPathTooSpreadOut hostName="JI2" pinName="IN" railType="ground" pathSpan="8.9" pathLength="18.52" message="Visible path from JI2.IN to ground spans 8.90 schematic units; move the connected support elements closer together near the pin and recompute their schematic traces." />
<RailPathTooSpreadOut hostName="JI3" pinName="IN" railType="ground" pathSpan="8.9" pathLength="18.52" message="Visible path from JI3.IN to ground spans 8.90 schematic units; move the connected support elements closer together near the pin and recompute their schematic traces." />
<RailPathTooSpreadOut hostName="JI4" pinName="IN" railType="ground" pathSpan="8.9" pathLength="18.52" message="Visible path from JI4.IN to ground spans 8.90 schematic units; move the connected support elements closer together near the pin and recompute their schematic traces." />
</SchematicPlacementIssues>