reports/routing-validation.json
{
"circuitPath": "dist/index/circuit.json",
"connectivityPreserved": true,
"nets": 53,
"connectedPins": 237,
"traces": 184,
"vias": 166,
"routed": true,
"errors": [
{
"type": "pcb_trace_too_long_error",
"pcb_trace_too_long_error_id": "pcb_trace_too_long_error_0",
"error_type": "pcb_trace_too_long_error",
"message": "PCB trace is 11.54mm long, exceeding the 10mm maximum",
"pcb_trace_id": "source_trace_1_mst0_0",
"source_trace_id": "source_trace_1",
"actual_trace_length": 11.544172735478213,
"maximum_trace_length": 10,
"subcircuit_id": "subcircuit_source_group_0"
},
{
"type": "pcb_trace_error",
"pcb_trace_error_id": "pcb_trace_error_0",
"error_type": "pcb_trace_error",
"message": "PCB trace uses 2 vias, exceeding the 0 maximum",
"pcb_trace_id": "source_trace_0_mst0_0",
"source_trace_id": "source_trace_0",
"pcb_component_ids": [
"pcb_component_4",
"pcb_component_19",
"pcb_component_27"
],
"pcb_port_ids": [
"pcb_port_8",
"pcb_port_89",
"pcb_port_103"
],
"subcircuit_id": "subcircuit_source_group_0"
},
{
"type": "pcb_trace_error",
"pcb_trace_error_id": "pcb_trace_error_1",
"error_type": "pcb_trace_error",
"message": "PCB trace uses 2 vias, exceeding the 0 maximum",
"pcb_trace_id": "source_trace_1_mst0_0",
"source_trace_id": "source_trace_1",
"pcb_component_ids": [
"pcb_component_4",
"pcb_component_8",
"pcb_component_20"
],
"pcb_port_ids": [
"pcb_port_9",
"pcb_port_63",
"pcb_port_91"
],
"subcircuit_id": "subcircuit_source_group_0"
},
{
"type": "pcb_placement_error",
"pcb_placement_error_id": "pcb_placement_error_0",
"error_type": "pcb_placement_error",
"message": "Via pcb_via_19 violates copper-to-board-edge clearance (measured 0.158mm, required 0.200mm)"
}
],
"routingConstraintErrors": [
"RF_ANT violates the required top-only, no-via routing rule",
"XTAL_40M_FB violates the required top-only, no-via routing rule",
"XTAL_40M_OUT violates the required top-only, no-via routing rule"
],
"warningCount": 38
}