AnasSarkiz/NEMA14_CH32X035G8U6

A NEMA stepper motor is shown with proposed M3 screws/spacers, four wired motor leads and splices, and a JST SHR-04V-S connector.

Version
1.12.2
License
ISC
Stars
0

artifacts/edge-resistors/inner1-routing-review.json

{
  "scope": "Named, bounded routing exceptions; geometric/native/CAM checks are still mandatory",
  "allowed_nets": [
    "GND",
    "V3V3",
    "SLEEP"
  ],
  "maximum_signal_length_mm": 25,
  "reason": "Ground stitching belongs on the ground layer. The 3.3 V resistor branch and static A4988 SLEEP control use narrow corridors on inner1 in the fixed 35 mm outline; power screening and actual ground/copper connectivity remain required. No clock, USB differential pair or motor phase output is permitted by this exception.",
  "tracks": [
    {
      "trace": "same_side_repair_0_V3V3_0_layer_section_1",
      "net": "V3V3",
      "length_mm": 7.026151883657291,
      "minimum_width_mm": 0.16
    },
    {
      "trace": "same_side_repair_0_GND_0_layer_section_1",
      "net": "GND",
      "length_mm": 1.8318655602122738,
      "minimum_width_mm": 0.16
    },
    {
      "trace": "same_side_repair_1_SLEEP_0_layer_section_1",
      "net": "SLEEP",
      "length_mm": 18.39764037949244,
      "minimum_width_mm": 0.16
    }
  ],
  "high_frequency_or_phase_nets_allowed": false,
  "hardware_EMI_and_thermal_testing_completed": false
}