lib/subcircuits/PowerSupply_WindowModule.circuit.tsx
import type { SubcircuitProps } from "@tscircuit/props";
import "tscircuit";
import { ReverseBatteryProtection_TLV1805_SQJ461EP } from "./ReverseBatteryProtection_TLV1805_SQJ461EP.circuit.tsx";
import { SupervisorWatchdog_TPS3850 } from "./SupervisorWatchdog_TPS3850.circuit.tsx";
import { VoltageRegulator_LM73605 } from "./VoltageRegulator_LM73605.circuit.tsx";
// Both sheet-2 children use source-relative coordinates. Their documented
// Altium-origin difference is (0.509, -12.192) mm. Keep the source X offset and
// add a documented +1.6-mm native-sheet Y packing translation to bring the
// complete 3.3-V System Supply section closer to Reverse Battery Protection.
const REGULATOR_SHEET_2_OFFSET = { x: 0.509, y: -10.592 } as const;
// Uniformly place the complete source layout in the vertical center of the
// enlarged native sheet frame. This parent-only translation preserves every
// child coordinate and the exact relative offset between the two sections.
const MAIN_SUPPLY_SHEET_Y_OFFSET = 6.2;
/**
* Automotive-window-module power-supply composite backed by the verified
* shared nets in TI TIDA-050008:
*
* VBATT -> reverse protection / EMI filter -> VIN1 -> LM73605 -> +3.3V
* +3.3V -> TPS3850 supply monitor and window watchdog
*
* The native schematic sheets mirror the authoritative TIDA-050008 CAD:
* reverse-battery protection and the regulator remain on "Main Supply"
* (source sheet 2), while the TPS3850 remains on "Watchdog and Vref" (source
* sheet 3). The child sections keep their source-relative layouts. This
* parent joins only the verified sheet nets; it does not synthesize
* thresholds, timing, dividers, or grounding arrangements.
*
* Both sheet frames use native ANSI-B sizing, matching the released Altium
* title blocks. A uniform +6.2-mm parent translation centers the Main Supply
* layout vertically. The regulator child additionally receives the documented
* +1.6-mm Y packing translation above; no child geometry is scaled.
*/
export const PowerSupply_WindowModule = (props: SubcircuitProps) => (
<subcircuit routingDisabled {...props}>
<schematicsheet
name="main_supply"
displayName="Main Supply"
sheetIndex={0}
sheetSize="ANSI_B"
/>
<schematicsheet
name="watchdog_and_vref"
displayName="Watchdog and Vref"
sheetIndex={1}
sheetSize="ANSI_B"
/>
<net name="GND" isPowerNet isGroundNet />
<net name="V3_3" isPowerNet />
<ReverseBatteryProtection_TLV1805_SQJ461EP
name="reverseBattery"
schSheetName="main_supply"
schY={MAIN_SUPPLY_SHEET_Y_OFFSET}
/>
<VoltageRegulator_LM73605
name="regulator"
schSheetName="main_supply"
schX={REGULATOR_SHEET_2_OFFSET.x}
schY={REGULATOR_SHEET_2_OFFSET.y + MAIN_SUPPLY_SHEET_Y_OFFSET}
/>
<SupervisorWatchdog_TPS3850
name="supervisorWatchdog"
schSheetName="watchdog_and_vref"
/>
<trace
name="VBATT"
schDisplayLabel="VBATT"
from=".reverseBattery > .VBATT"
to="net.VBATT"
/>
<trace
name="VIN1"
schDisplayLabel="VIN1"
path={[".reverseBattery > .VIN1", ".regulator > .VIN1", "net.VIN1"]}
/>
<trace
name="V3_3"
schDisplayLabel="+3.3V"
from=".regulator > .V3_3"
to="net.V3_3"
/>
<trace
name="V3_3"
schDisplayLabel="+3.3V"
from=".supervisorWatchdog > .V3_3"
to="net.V3_3"
/>
<trace
name="GND"
path={[".reverseBattery > .GND", ".regulator > .GND", "net.GND"]}
/>
<trace name="GND" from=".supervisorWatchdog > .GND" to="net.GND" />
<trace
name="V_CTRL1"
schDisplayLabel="V_CTRL1"
from=".regulator > .V_CTRL1"
to="net.V_CTRL1"
/>
<trace
name="WDI"
schDisplayLabel="WDI"
from=".supervisorWatchdog > .WDI"
to="net.WDI"
/>
<trace
name="WDO"
schDisplayLabel="WDO"
from=".supervisorWatchdog > .WDO"
to="net.WDO"
/>
<trace
name="RESET_3V3"
schDisplayLabel="3.3RESET"
from=".supervisorWatchdog > .RESET_3V3"
to="net.RESET_3V3"
/>
<port name="VBATT" direction="left" connectsTo="reverseBattery.VBATT" />
<port name="GND" direction="left" connectsTo="reverseBattery.GND" />
<port name="V3_3" direction="right" connectsTo="regulator.V3_3" />
<port name="V_CTRL1" direction="right" connectsTo="regulator.V_CTRL1" />
<port name="WDI" direction="left" connectsTo="supervisorWatchdog.WDI" />
<port name="WDO" direction="right" connectsTo="supervisorWatchdog.WDO" />
<port
name="RESET_3V3"
direction="right"
connectsTo="supervisorWatchdog.RESET_3V3"
/>
</subcircuit>
);
export default PowerSupply_WindowModule;