mohan-bee/pcb
This circuit integrates an ESP32 microcontroller with an IMU sensor and power management components, using multiple capacitors, resistors, and MOSFETs for motor control, while managing power supply and battery connections.
- Version
- 1.0.0
- License
- unset
- Stars
- 0
schematic-check.log
Detected entrypoint: 'index.circuit.tsx'
Each child in a list should have a unique "key" prop.
Check the render method of `board`. It was passed a child from Drone. See https://react.dev/link/warning-keys for more information.
trace: `key` is not a prop. Trying to access it will result in `undefined` being returned. If you need to access the same value within the child component, you should pass it as a different prop. (https://react.dev/link/special-props)
<SchematicBoxPositions>
<SchematicBoxPlacement componentName="U1" positionAnchor="center" schX="0" schY="16" width="1.2" height="6.2" />
<SchematicBoxPlacement componentName="COUT1" positionAnchor="center" schX="35" schY="8" width="0.9" height="0.6" />
<SchematicBoxPlacement componentName="COUT2" positionAnchor="center" schX="38" schY="8" width="0.9" height="0.6" />
<SchematicBoxPlacement componentName="CESP" positionAnchor="center" schX="0" schY="8" width="0.9" height="0.6" />
<SchematicBoxPlacement componentName="CESPHF" positionAnchor="center" schX="3" schY="8" width="0.9" height="0.6" />
<SchematicBoxPlacement componentName="CIMU" positionAnchor="center" schX="32" schY="-12" width="0.9" height="0.6" />
<SchematicBoxPlacement componentName="CIMUB" positionAnchor="center" schX="35" schY="-12" width="0.9" height="0.6" />
<SchematicBoxPlacement componentName="CIO" positionAnchor="center" schX="38" schY="-12" width="0.9" height="0.6" />
<SchematicBoxPlacement componentName="REN" positionAnchor="center" schX="0" schY="5" width="0.9" height="0.6" />
</SchematicBoxPositions>
<SchematicPlacementIssues>
<TraceCanBeSimplifiedByMovingComponent schematicTraceId="schematic_trace_59" targetComponentName="REN" deltaSchX="-2.181" deltaSchY="0" newSchX="-2.181" newSchY="5" currentTurnCount="3" suggestedTurnCount="1" message="move REN left by 2.181 (to schX=-2.181, schY=5) to reduce this trace from 3 turns to 1" />
<DecouplingCapacitorsNotCloseTogether rail="V3V3" ground="GND" capacitorNames="COUT1, COUT2, CESP, CESPHF, CIMU, CIMUB, CIO" maxBodyGap="41.866" maxRecommendedBodyGap="4" message="Group the decoupling capacitors between V3V3 and GND closer together in this schematic block. Preserve their net connections." />
</SchematicPlacementIssues>