import { INA226AIDGSR } from "../imports/INA226AIDGSR";
import { revisionPlacement } from "../mechanical/revision-placement";
import { logicTrace, schematicSections, schematicSheets } from "./config";
const section = {
schSheetName: schematicSheets.motorPower,
schSectionName: schematicSections.pdMonitor,
} as const;
/**
* INA226's independent, high-voltage VBUS ADC measures the charger output before
* the fuse and blocking diode. Unlike an RP2040 GPIO divider, VBUS may remain at
* 20 V when the DATA USB and the INA226's 3.3 V supply are disconnected.
*/
export const PdBusVoltageMonitorSection = () => (
<>
<INA226AIDGSR
name="U_PD_MON"
layer="top"
noConnect={["Alert"]}
{...section}
{...revisionPlacement("U_PD_MON")}
schWidth={1.85}
schHeight={1.5}
schPinArrangement={{
leftSide: { pins: [8, 10, 9], direction: "top-to-bottom" },
rightSide: { pins: [4, 5, 3], direction: "top-to-bottom" },
topSide: { pins: [6], direction: "left-to-right" },
bottomSide: { pins: [1, 2, 7], direction: "left-to-right" },
}}
/>
<capacitor
name="C_PD_MON"
layer="top"
capacitance="100nF"
footprint="0402"
supplierPartNumbers={{ jlcpcb: ["C1525"] }}
maxDecouplingTraceLength={4}
{...section}
{...revisionPlacement("C_PD_MON")}
schOrientation="vertical"
/>
<trace name="PD_MON_VBUS" from=".J_MOTOR_USB > .A4B9" to=".U_PD_MON > .VBUS"
schDisplayLabel="PD_VBUS_RAW" {...logicTrace} />
{/* No current shunt is fitted: keep the differential input at 0 mV. */}
<trace name="PD_MON_IN_POS" from=".U_PD_MON > .VIN_POS" to=".U_PD_MON > .VBUS" {...logicTrace} />
<trace name="PD_MON_IN_NEG" from=".U_PD_MON > .VIN_NEG" to=".U_PD_MON > .VBUS" {...logicTrace} />
<trace name="PD_MON_VS" from=".MCU > .L_AVDD > .pin1" to=".U_PD_MON > .VS_POS"
schDisplayLabel="V3V3" {...logicTrace} />
<trace name="PD_MON_BYPASS" from=".U_PD_MON > .VS_POS" to=".C_PD_MON > .pin1"
schDisplayLabel="V3V3" {...logicTrace} />
<trace name="PD_MON_BYPASS_GND" from=".C_PD_MON > .pin2" to="net.GND" {...logicTrace} />
<trace name="PD_MON_GND" from=".U_PD_MON > .GND" to="net.GND" {...logicTrace} />
<trace name="PD_MON_ADDR0" from=".U_PD_MON > .A0" to="net.GND" {...logicTrace} />
<trace name="PD_MON_ADDR1" from=".U_PD_MON > .A1" to="net.GND" {...logicTrace} />
<trace name="PD_MON_SDA" from=".U_PD_MON > .SDA" to=".U_TEMP > .SDA"
schDisplayLabel="TEMP_SDA" {...logicTrace} />
<trace name="PD_MON_SCL" from=".U_PD_MON > .SCL" to=".U_TEMP > .SCL"
schDisplayLabel="TEMP_SCL" {...logicTrace} />
</>
);